Features
|
| Advanced user-friendly Micro-Processor Controller, state-of-the-art design with alphanumeric splash-proof soft keyboard and interactive software in dialogue mode for ease of operation with protection against invalid entries. |
| Vortex stirrer for vigorous and homogenous stirring, with specially designed glass propeller for chemical inertness. |
| A quickly interchangeable calibrated burette with intelligent recognition for its volume size. Burette factor for dispensing corrections, also available for true end point calculations. |
| Temperature Sensor with 4-line measurement technique ensures correct temperature indication. |
| Composite Differential Electrode Amplifier unit for Potentiometric and Voltametric/Karl Fischer Titrations, with connectivity to various electrodes. |
| During titration, measured variables or the pH value is shown on the display together with dispensed volume and number of EP’s detected. |
| User selectable End Point (EP) evaluation up to 9 EP’s during the run, and calculation by first, last, largest, all or selected EP’s with display of results and printout. |
| Reprocessing of threshold and recalculation of EP without performing the new run. |
| Alphanumeric entry of sample name, titrant name, identification number, date with type of electrode used for authentication. |
| Daily auto incremented run number and factory entered customer name and instrument Serial Number shown on report printouts, making the system Fully GLP Complaint. |
| Dispenser facility for fixed volume dosing or dilution, allowing manual titration with user defined dose and mV indication. |
| Pre-dispense facility with selectable dose and time, for quick titrant without disturbing the titration trend. |
|
Specifications
|
| Principle |
Volume determination by equivalent point, end point or pH STAT |
| Control |
Micro-Processor based |
| mV Range |
=/- 3200mV |
| Accuracy |
+/- 0.1mV (+/- 0.0016pH) |
| Amplifier Input Impedance |
>1012 Ohms |
| Burette Resolution |
1/5000 for 5ml, 1/10000 for 10ml, 1/50000 for 25ml |
| Filing Time ? |
<20S |
| Keyboard |
Alphanumeric splash-proof polyester soft keys. |
| Titration Head |
Manual Stand with swivelling arm |
| Stirrer System |
Microcontroller based variable speed, high torque vortex stirrer with digital indicator. (Magnetic Stirrer Optional) |
| Sensors |
· Electrodes for Potentiometric titration (pH, Ion, Redox, Argentometric) · Any Combination Electrode · Differential Electrode System comprising sensing (indicator) Electrode with various adaptors such as BNC connector, and Reference Electrode with 4mm Connector · Electrode for Karl Fischer with BNC/TNC Connectors · Temperature Sensor. |
| Calibration |
3-point Calibration with entered buffer values and standardisation with pH 7 Buffer |
| End Point Detection |
· Potentiometric · Voltametric · Thermometric & Photometric |
| Cut-off Criteria |
· Volume · End Point · mV/pH |
| Analysis Methods |
· Titrations · Acid -Base · Non-aqueous · Redox · Precipitation · Complexometric · Back Titration · Karl Fischer |
| Results & Concentration Units |
· Molarity · % Assay (wt) · % Volume (ml) · ppm, mg/l, mg/g, g/l, meq/l, mol/kg, TAN and TBN for Oil Sample |
| Method Storage |
50 methods with Parameters |
| Titrant Molarity Storage |
20 Values |
| Report Format |
· Method Parameters · Titration Analysis Report · Titration Analysis Condensed Report · Titration Data Table · Titration Graphic Report · Micro Litre v mV · Micro Litre v First and/or Second Derivative · Micro Litre v Time · Auto Evaluation Report · Statistics Report · End Point Titration Report · Calibration Report |
| ?Input/Output peripheral Interface |
?· Parallel Port for Printer · Serial Ports for Balance, Auto-Sampler and PC ? |
| Power |
??110V/ 230V 50Hz/60Hz ? |
| Environmental Conditions for Operation |
· Laboratory Use · Temperature Ambient to 45°C · Humidity 5 - 90% Non Condensing |
|